ECM Series - 3 Phases Energy meter

ECM6-E MID

ECM6-M MID

ECM6 MID

ECM6-S MID

ECM80-E MID

ECM80-M MID

ECM80 MID

ECM80-S MID

WECM Series - 1 Phase Energy meter

WECM40-M MID

WECM40 MID

WECM40-S MID

WECM80-E MID

WECM80-M MID

WECM80 MID

WECM80-S MID

Specifications:

Basic data:
  • Certified MID version
  • For Ethernet communication (Modbus TCP)
  • For 1 or 5A transducer
  • Programmable transformer ratio
  • Fully bi-directional four-quadrant measurements for all energies and powers
  • For 4-wire networks with symmetrical or asymmetrical load
  • Class B according to EN 50470-3
  • S0 output for energy pulse delivery
Measurement
Active energy accuracy
Class B according to EN 50470-3
Reactive energy accuracy
Class 2 according to IEC/EN 62053-23
Starting current
2 mA
Minimum current
10 mA
Transition current
50 mA
Rated current
0 – 6 A
Nominal current
1 A
– burden
< 0.04 VA
Frequency
50 – 60 Hz
Communication
Normative standards
IEEE802.3
Interfaces
Ethernet (10/100 Base T)
Protocols
Modbus TCP/IP, HTTP, NTP, DHCP
speed
10/100 Mbps
Webserver; 8MB Data storage

Advanced equipment - Optimal Solution.